Approvals

NordicFlow Jockey Pumps (Data Sheet)

NordicFlow Jockey Pumps

NordicFlow Jockey Pump keeps the system pressurized during normal conditions and prevents unnecessary activation of the main pump.

Type: Multistage centrifugal pump
Liquid Temperature: -20ºC – +120ºC
Flow Range: 0,7-120 m3/h
pH: 4-10
Max. pressure: 33 bar
Ambient Temperature: max. 40ºC
Altitude: up to 1000 m

Ambient Temperature

Max +40ºC. Ambient Temperature above 40ºC or installation at an altitude of more than 1000 meters above sea level requires the use of an oversize motor. Because of low air density and poor cooling effects, the motor output power P2 will be decreased (see figure). In such cases, it may be necessary to use a motor with higher output power rating.

LVR3 lämpötila

Motor

  • Totally enclosed and fan-cooled
  • Protection Class: IP55
  • Standard Voltage: (50 Hz) 1x220V / 3x380V

Stock Product Information

Product code Rated flow Rated head Max. flow Max. head Max. inlet pressure Motor power Pipe connection Voltage
LVR3-7-220V 3 m3/h 32 m 5 m3/h 44 m 10 bar 0,55 kW G 11/4 220V / 50Hz
LVR3-7-380V 3 m3/h 32 m 5 m3/h 44 m 10 bar 0,55 kW G 11/4 380V / 50Hz
LVR3-9-220V 3 m3/h 42 m 5 m3/h 57 m 10 bar 0,75 kW G 11/4 220V / 50Hz
LVR3-9-380 3 m3/h 42 m 5 m3/h 57 m 10 bar 0,75 kW G 11/4 380V / 50Hz

Curve Charts

LVR3 curve chart 1
* The thin curves indicate the duty range where long-time operation is forbidden. * The bold curves indicate the recommended duty range for best efficiency. * Numbers on thin curves indicate the number of stages.
LVR3 curve chart 2
* Eta = operating efficiency * P2 = power output of single impeller * QH2900rpm = single impeller Q-H curve * NPSH = Net Positive Suction Head